Warenkorb Übersicht
Total:
  • ShopSHOP
  • ShopKnow-How
  • ShopSUPPORT
Measurement Computing
search
Produktbezeichnung Alles
  Erweiterte Produktsuche
EmailE-mail Call MeRufen Sie an
07142-9531-0
Wir helfen Ihnen gerne
International Languages   Easy to Use  |  Easy to Integrate  |  Easy to Support   International Distributors
Data Acquisition Companion Software   DASYLab DAQ Software

Data Acquisition Product Selection Catalog   MCC Data Acquisition eNews

Learn about Data Acquisition

usb-1608G-rban.jpg

TracerDAQ®

Virtuelle Instrumente Out-of-the-Box

2.7 ratings  2,7   (3 customer reviews)
Product Q&A     8 Questions | 8 Answers     Read all Q&A
 
TracerDAQ®


[+] View Larger Image

Key Highlights

Messdaten innerhalb kürzester Zeit erfassen, analysieren, anzeigen, sowie Signale ausgeben

Keine Programmierung erforderlich

Einfacher Export der Messdaten nach Excel®

Wird auf jeder MCC DAQ CD mitgeliefert

Erweiterung verfügbar: TracerDAQ Pro Professionelle Virtuelle Instrumente

Unterstützte Betriebssysteme: Windows® 10/8/7/Vista®/XP SP2, 32 Bit oder 64 Bit

Download MCC DAQ CD

TracerDAQ Hilfe

Vergleich zwischen TracerDAQ und TracerDAQ Pro


Klicken Sie hier, falls Sie Probleme beim Betrachten von YouTube Videos haben.

software Software and Driver Downloads

  • Pricing
  • Reviews
  • Q & A
  • Overview
Part Number Description
Prices shown are in U.S. dollars for orders placed within the U.S. For international orders, please contact one of our distributors in your area.
TracerDAQ® Virtuelle Instrumente out-of-the-box, mit Linienschreiber, Oszilloskop, Funktionsgenerator und Taktgenerator
Included

Product Reviews

2.7 / 5

Ease of UseValueTechnical Support
3,7 / 5 3,7 / 5 2,7 / 5

33% of reviewers recommend this product.

Page 1 of 1
1/5 Mai 22, 2014
TracerDAQ is full of bugs - user beware!!

This software is full of bugs. It crashes when certain options are selected when setting up the configuration. Sometimes the markers freeze in the strip chart and cause it to crash. There is a feature in the strip chart that calculates the difference between the markers, but it actually calculates the absolute value sum of both marker positions One of the biggest problems is that at startup the application screens don't size correctly and they get loaded off-screen. When this happens, you can't see the application windows buy they are running...somewhere. TracerDAQ is half baked and should not have been released in this state. I have had it for over a year now and each time I use it, I encounter new bugs and problems.

Job Title: Electrical Engineer


Response from MCC
, Marketing
Mai 22, 2014
Hello EEGuy - You are likely using version 2.2 of TracerDAQ. We have since released an improved version (2.3) in which we fixed one known cause of crashes. Version 2.3 also corrects for the issue whereby, if you have TracerDAQ’s stripchart minimized at the time the PC is shut down, the stripchart comes up minimized the next time. Version 2.3 can be obtained as part of the free MCCDAQ CD download, version 6.30 or higher. We recommend updating InstaCal at the same time, which is part of the same download. As for the markers, you are correct that the time delta between the two markers is returned as an absolute value (positive time only), but the voltage difference is returned as a true positive or negative. If you still have issues after updating to version 2.3, please provide details to our technical support group.
Was this review helpful? Yes (1) / No (0)

From: USA
Company Size: 1-100
Software Used: TracerDAQ
Ease of use

Value

Technical Support
5/5 Mai 14, 2014
Students like it

Use this to stream raw data in. Students can watch data trends then export to Matlab and post process. Up and running quick accurate time base, blows LabView away.

Job Title: Instructor
Industry: Education/research

Yes, I recommend this product

Was this review helpful? Yes (2) / No (0)

From: Cambridge, MA, USA
Company Size: 1-100
Software Used:
Ease of use

Value

Technical Support
2/5 August 27, 2013
Crashes Windows a lot otherwise OK

If the window is not minimized, sometimes when you move an active program window over it, the TracerDAQ display locks up and you have to use Task Manager to close it. Sometimes closing it in this manner crashes Windows. There are also bugs with what is probably array over-run or index mismatching that will crash it; it won't save the file and won't operate correctly without closing it all down and restarting. When it starts it doesn't remember where you last stored data. If you move a channel from one lane to another all the display settings go back to default and you have to set them up again. What a pain. Otherwise it's useful and beats having to write charting code.

Job Title: Owner
Industry: forensic engineering and car racing
Application: continuous temperature monitoring
Was this review helpful? Yes (2) / No (1)

From: Indio, CA, USA
Company Size: 1-100
Software Used: TracerDAQ
Ease of use

Value

Technical Support

Product Q & A




The TracerDAQ does not detect the hardware , how I can set the hardware ?

Job Title: battery Engineer
Industry: Automotive
Application: battery temperature record


16 months ago

Mohammad Cincinnati, OH


Answers
Before launching TracerDAQ, you must first run InstaCal - to have the hardware recognized (and possibly also configure the hardware). Then close InstaCal and re-launch TracerDAQ.

16 months ago

Measurement Computing

Was this Answer helpful? Yes (1) / No (0)

Is it possible to use PMD-1208LS with TracerDAQ

I am trying to record a data with PMD-1208LS. Is it possible to use it with TracerDAQ Thanks

Job Title: Research Assistant
Industry: Civil Engineering
Application: Seismic Data Recording


17 months ago

Ridvan Kalamazoo


Answers
Hello, Yes - the PMD-1208LS (now the USB-1208LS) is compatible with TracerDAQ.

17 months ago

Measurement Computing

Was this Answer helpful? Yes (1) / No (0)

Marker Values on Strip chart doesn't work

Marker values just display 0.00 while graphing and output works.

Job Title: Acoustics Tech
Industry:
Application:


23 months ago

ShawnP Framingham, MA


Answers
The marker values do start at zero. The markers values are updated each time you move (with the mouse) one or the other marker. i.e. live data scrolling across the screen, in and of itself, does not update the marker values.

23 months ago

Measurement Computing

Was this Answer helpful? Yes (0) / No (0)

Is there any option to create RMS values over time?

I need data logged over long periods of time (hours). If I set it to sample slow enough so that the on-board storage doesn't fill up, I only get say 1 data point per second. My signal is something like a PWM, so I end up getting random points between 0 and 1. Instead I need it to sample fast, create an RMS value, and then just store the RMS value rather than tons of data points. Is there any way to create long strip charts that don't just sample 1 point per second or so? Instead, I need something like 1000 points per second, averaged into 1 point per second.

Job Title: Component Design Engineer
Industry: Consumer Electronics
Application:


24 months ago

horta1212 Columbia, SC


Answers
Hello - TracerDAQ PRO does not offer any averaging capability. You should consider DASYLab Lite, as it can perform RMS (Quadratic Mean) in its Averaging module. A free 28-Day Evaluation version of DASYLab may be downloaded from: http://www.mccdaq.com/DASYLab-Resources.aspx

24 months ago

Measurement Computing

Was this Answer helpful? Yes (0) / No (0)

TracerDAQ error after reinstalling windows 7

After reinstalling windows 7 and installing tracerDAQ, when started the program encounters an error that states "Input string was in incorrect format." and does not load. Reinstalling tracerDAQ several times did not help.

Job Title: Technical Assistant
Industry: Research&Development (university)
Application:


26 months ago

STigges Duisburg, Germany


Answers
This error message is relatively new, but as of yet has not been very common. We have not been able to duplicate it ourselves, and do not yet know a solution, but it is possible that the following FAQ will help: http://kb.mccdaq.com/KnowledgebaseArticle50559.aspx

26 months ago

Measurement Computing

Was this Answer helpful? Yes (0) / No (0)

Can recorded data files be played back on analog outputs?

Job Title: Owner
Industry:
Application:


26 months ago

BK0630 United States


Answers
TracerDAQ does not support the use of an arbitrary file for outputting analog data. However, TracerDAQ PRO does. The file must be in .CSV or .TXT format and you can easily convert your TracerDAQ PRO strip chart data file to either format within the application. One caveat is that TracerDAQ PRO, along with the data includes information regarding the experiment in a header that is not compatible with the function generator and needs to be edited out. You will have to open the .CSV or .TXT file and edit this out prior to using it with the function generator. Please feel free to contact us if you have any further questions.

26 months ago



Was this Answer helpful? Yes (2) / No (0)

Sample size not working

Hi, when I open strip chart software on tracerdaq and try to set the scan rate to 500 HZ it says the maximum time frame data can be recorded is 1 minute an 4 seconds (only 32,000 samples). From your product page it says it can record up to a million samp



30 months ago

JoseC


Answers
Hello JoseC - The standard version of TracerDAQ can sample up to 32,000 samples per channel. The PRO version, sold separately, is the one that can sample up to 1,000,000 samples per channel. More information on TracerDAQ Pro may be found at: http://www.mccdaq.com/daq-software/tracerdaq-pro.aspx A comparison chart showing the differences between the Standard and Pro versions may be viewed at: http://www.mccdaq.com/td-compare.aspx

30 months ago

MeasurementComputing

Was this Answer helpful? Yes (0) / No (0)

Strip chart not displayed.

When I open the strip chart a button shows up on the task bar but I do not get a strip chart display on the screen. How do I get the main display?

Job Title: Technician
Industry: Electronics
Application: We build oceanographic research instrumentation


39 months ago

RossG Wetlabs


Answers
Hi Ross - This quirk was fixed recently in TracerDAQ 2.3.0.0. In earlier versions, if you shut down your PC when TracerDAQ was minimized, TracerDAQ comes up the next time as minimized. You should be able to enlarge it by right clicking on it in the task bar. If you are using Windows7, you may first need to left click to pick which of the two TracerDAQ windows on the task bar you wish to reference, and then right click, and select “Maximize”.

39 months ago

MeasurementComputing

Was this Answer helpful? Yes (2) / No (0)

Zusammenfassung

TracerDAQ bietet vier virtuelle Instrumente zur Anzeige und Speicherung von Messdaten, sowie zur Ausgabe von Daten innerhalb weniger Minuten nach der Installation eines Messgerätes von Measurement Computing. Die Anwendung erlaubt das Anpassen der Benutzeroberfläche und das Speichern unterschiedlicher Konfigurationen. Daten können für den späteren Export gespeichert und bestimmte Einstellungen auch während der Erfassung geändert werden.

Strip Chart Linienschreiber: Ein 8-Kanal Linienschreiber zum Speichern und Visualisieren von analogen und digitalen Messdaten, Zählerwerten und Temperatureingängen eines Measurement Computing Messgerätes. Bis zu 32.000 Messwerte pro Kanal können mit der Abtastrate der Messkarte erfasst werden.
Oscilloscope Oszilloskop: Ein 2-Kanal Oszilloskop visualisiert die Messdaten der analogen Eingänge. Daten werden mit der Abtastrate der Messkarte erfasst, getriggert per Software oder einem externen Triggersignal.
Function Generator Funktionsgenerator: Ein 1-kanaliger Sinus-Funktionsgenerator, der Werte mit der maximalen Ausgaberate der Hardware ausgeben kann. Der Funktionsgenerator zeigt die auszugebende Wellenform, Zahl der Ausgabewerte pro Periode, interne Messwertrate, Grundfrequenz, Amplitude und DC-Offset des analogen Ausgangssignals.
Rate Generator Taktgeber: Ein 1-kanaliger Taktgeber, der auszugebende Wellenform, Anzahl Werte pro Periode, interne Datenrate und Grundfrequenz der Counter/Timer Ausgabe zeigt. Frequenz, Tastverhältnis und Anfangszustand der Funktion können eingestellt werden.